Effect of SiC/ ZrC Precursor Ratio on Ablation Property of C/ C-SiC-ZrC Composites
DOI:
Author:
Affiliation:

Clc Number:

TB332

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The C/ C-SiC-ZrC composites were prepared by precursor impregnation and pyrolysis method (PIP)
    using different mass ratio of PCS/ PZC as impregnant. The microstructure and the ceramic phase distribution of the C/
    C-SiC-ZrC composites before and after ablation were examined. And the effect of SiC/ ZrC precursor ratio on the ab-
    lation property of the C/ C-SiC-ZrC composites was analyzed. The results show that the mass ablation rate and linear
    ablation rate of the C/ C-SiC-ZrC composites were decreased firstly and increased subsequently with the increasing of
    the content of ZrC. The composite possessing the relatively best ablation performance was fabricated with the impreg-
    nant with the mass ratio of PCS/ PZC =1 ∶3. After ablation on oxyacetylene flame with the surface temperature of 3
    000℃, the mass ablation rate and linear ablation rate of the sample are -0. 65 mg/ s and 21 μm/ s, respectively. Too
    much or less ZrC in SiC-ZrC multiphase ceramics is not favorable to the oxidation stability of the samples. Therefore,
    appropriate ZrC may be better.