Failure Analysis of Fractured 30CrMnSiNi2A Stud Bolt
DOI:
Author:
Affiliation:

Clc Number:

TB31

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Seven stud bolts bending two cabins were found fractured after the separation device being static tested.
    The surface of bolts was done by Dacromet treatment. Observation on fracture surface and analysis of experiment
    all indicate property of delayed brittle fracture caused by hydrogen embrittlement. Besides the bolt material’ s high
    susceptibility to hydrogen embrittlement, the long time wet coating on bolt during testing largely led to the fracture. Analysis
    indicates that high tensile steel-made item after Dacromet coating treatment is still subject to hydrogen embrittlement
    fracture that causes serious consequence under tensile stress in circumstance where water and corrosive medium
    such as Cl, S exists although Dacromet coating treatment effectively prevent the item from hydrogen embrittlement
    in surface processing period. This conclusion may serve as precaution to those who design and use high tensile steel
    under similar circumstance.

    Reference
    Related
    Cited by
Get Citation
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: November 28,2016
  • Published: