Wing Leading Edge Ablation Tests in Arc Tunnel
DOI:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    This paper reports the results of ablation tests conducted in FD04 arc tunnel of China Academy of
    Aerospace Aerodynamics (CAAA) for the development of wing leading edge thermal protection materials. The models
    were made of high temperature ceramic(HTC), with swept angle 53, height 75 mm, long 55 mm, leading edge radius 2 mm and symmetric cross section made up of a 5wedge on each side. The test facility included 20 MW arc heat
    er, mixing chamber, rectangular supersonic nozzle, test box, trajectory simulation and vacuum system etc. The rectangular supersonic nozzle with Mach number 3. 6 was used in tests. The aero heating conditions of the wing leading
    edge were simulated by a test trajectory with flow field parameters of three steps. The test duration was 77. 0 s. The
    results show that HTC has well ablation performance, and two models had no breakage during the tests. The inner
    temperature responses are attained in tests.