Abstract:Electric equipment suffers dynamic load such as vibration and shock at work, as a result, failing to
work normally as the response exceeded its tolerance, thus the damping design was applied to reduce vibration and absorb
shock. Tests results show that vibration reduction efficiency is larger than 55 percent,magnification of shock response
is less than 1. 6, and the work environment of electric equipment is improved efficiently.