Abstract:Multi-layerednanoporous-insulationmaterialswerepreparedwiththinnanoporous-insulationmaterials
andmetallicfoils,Insulationperformanceofdifferentstructuresweretested.Theresultsindicatedthatusingmoremetallicfoillayers,
placingstainlesssteelinlowtemperaturezone,orusingaluminumfoilinsteadofstainlesssteelfoilinlow
temperaturezoneandtestingathighertemperaturewereofadvantagetoinsulationperformance.