Abstract:The ultrasonic resonant NDT technique was analytically discussed and the inspection technology of
composite bond structures was studied with the developed ultrasonic resonant equipment,the result suggests that the
debond defects more than 10 mm in the bond structures for the composite layer of 7 mm thick, and the debond defects more than 15 mm in the bond structures for the composite layer of 9 mm thick can be found out.