    摘要:

    研制了一套顶杆法膨胀仪,用于测试室温~500℃固体材料的平均线胀系数。利用该套膨胀仪对
    SRM732 进行测试,并与美国国家标准与技术研究院提供的标准数据比较,相对误差小于2%。以SRM732 测
    试结果为基础,进行不确定度分析,该套膨胀仪的测试不确定度小于3. 2%。

    Abstract:

    Push-rod dilatometer has been developed for measuring linear thermal expansion coefficients of solid
    materials for thermal expansion from the room temperature to 500℃. The linear thermal expansion coefficients of single-
    crystal sapphire have been determined using the Push-rod dilatometer. The present data are compared with the data
    recommended by the National Institute of Standards and Technology ( NIST), which are in good agreement. The
    relative uncertainty in the measurement was estimated to be less than 4% in the temperature range, based upon the
    data of single-crystal sapphire. 